主题: hard anodising
查看单个帖子
旧 2009-09-05, 10:54 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 hard anodising

hard anodising
i have a 7075 thread that has been hard anodised instead of sulphuric anodised and i have to determine the effect on fatigue life. anyone know where i can get data on comparable fatigue life after hard anodising?
find a job or post a job opening
here are some threads from this site. also, have you checked mil std 8625 for any data on this subject
you might assume the existence of the minimum depth crack you can't find under dye-penetrant inspection. then calculate crack propagation using nasa flagro or the current equivalent.
with hard-anodizing and the stress-concentration of a thread form (see peterson), i would expect cracking immediatly upon preloading.
the sulphuric acid process itself does not guarantee an improvement; it's the boiling-water sealing step that forms a relatively amorphous emulsion which should be more crack-resistant.
?why anodizing? there are many other more historical protective processes, including mil 5541 (alodine) and wet installation with epoxy primer.
i've never seen any actual data on any of the above.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖