默认 cip wall control 9contraction0 joints

cip wall control (contraction) joints
please see
typical joints i place around 20 to 25 ft depending on wall thickness and reinforcing. i would try to avoid joints over openings, one reason so i wouldn't have a potential plane of differential movement in an eq directly over a window or door.
i usually place control joints in the 25 feet to 30 feet range. construction joints would then be every other joint or 50 to 60 feet. if it is a exterior retaining wall, i also provide an expansion joint at every 4th joint or 100 to 120 feet.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]