cyclic test results for moment connections
cyclic test results for moment connections
in ibc 2000 for special moment frames reference is made to aisc's siesmic provisions part i and iii. in order to design special or intermediate moment frames column to beam connections, cyclic test results are required for similar projects. where are the test results available?
fema350 is a design guide for steel frames and the moment connections. you can obtain a copy (free) by calling 1-800-480-2520.