默认 vertical seismic force for asce 7-05

vertical seismic force for asce 7-05
as per 12.14.3.1.2, vertical effect should be considered if sds>=0.125. is that rignt?
but i can't find ths same requirement in ibc 2006, and seems not too much engineer used it.
ibc 2006 section 1613 says to use asce 7-05.
section 1605.4 defines em, as based on requirements in asce7 section 12.4.3, which in turn refers to asce7 section 12.4.2.2. the same exception for sds <= 0.125 exists there.
thank you.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖