默认 wind load due to wind along plane of frame

wind load due to wind along plane of frame
a junction house of belt conveyors is supported in one of the planes on 3 braced columns in a plane.to calculate wind force on the structure when wind flows along this plane i also need to find udl of wind load on these columns .columns are 16 m tall and spaced at about 6m each.i get the force coefficient for a single column as 2 from standards . this multiplied by width *height gives the total wind force on column in this direction.now for wind force on total frame consisting of 3 columns (for bracing some 25% of force on a single column can be added)do i multiply this force by 3 or will their be some shielding effect?
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]