旧 2009-09-07, 11:51 AM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 anchor bolts in concrete for wood frame construction

anchor bolts in concrete for wood frame construction
concrete foundation wall to timber sill plate anchorage using 1/2" diameter anchor rods.
i am looking at the ibc new york state edition "residential code of new york state" (rcny). for those who have a copy, on page 60, it states "... anchor bolts spaced a max of 6 ft on center" probably says this in all editions of the ibc.
clear enough.
the same code (page 25) states "construction in regions where the basic wind speed exceeds 110 mph (my situation) shall be designed in accordance with:
(1) wood frame construction manual 1995 edition....
looking at wfcm, for prescriptive requirements (page 113).
for anchorage, for sill plate to foundation, for 2 story homes, it calls for 23 inches spacing using 1/2 inch anchor bolts (presumably the rcny meant 1/2" also) for lateral and shear loads, and 72 inches (ok the same 6 ft) for uplift.
so does the wfcm govern for lateral loads? i have never seen a project with anchor rods spaced at 23 inches.
by the way, for wind speed clarification, the rcny states that 110 mph basic wind speed equals 90 mph fastest mile wind speed, which is the way it is shown in the wfcm tables.
i am also specifying stainless steel anchor bolts because of the acq issue in treated lumber. am i the only one? i get that feeling when residential construction contractors see it.

i can not comment on the spacing requirements.
the information sheet found here;
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
5 concrete garage floor over wood frame huangyhg 产品功能分析 0 2009-09-07 08:49 AM
30mpa parking garage concrete slab vs. 35mpa huangyhg 产品功能分析 0 2009-09-07 08:39 AM
3000 psi concrete requiremen huangyhg 产品功能分析 0 2009-09-07 08:39 AM
28 day vs. 56 day concrete breaks huangyhg 产品功能分析 0 2009-09-07 08:34 AM
【转帖】asme美国机械工程师标准目录2 huangyhg American standards 5 2009-04-26 02:38 PM