默认 concrete spec. for hot tub

concrete spec. for hot tub
i have been tasked with designing the reinforcing for a custom in ground hot tub, as well as the type of concrete to use. i am considering a sand/gravel mix. is a silica concrete necesary? the hot tub is outdoors in the plains area of the u.s. (freeze/thaw), so air entrainment is typical. shotcrete construction is not going to be used. typical formed concrete walls with integral concrete seats. i am planning on a slab foundation, water bars at all pour joints (vert. as well as hor.), and drain tile around the perimeter. there are three floor heights, so there will be sand fill below the slabs as well as drain tile on the interior. the slabs will be tied into the walls with reinforcing (and water bar). does anyone have anything to add? should i consider the use of fiberglass reinforcing for the slabs instead of welded wire mesh? would the use of epoxy coated rebar be considered?
find a job or post a job opening
you may want to insulate the tub base and sides if frost heave is an issue, or have founding of the sides below frost level. floor can be cast on a void if soil heave is an issue. i'd probably opt for epoxy coated wwm or rebar, just to minimize any rusting stains if rebar is too close, or if a minor crack occurs.
use absolute minimum slump to minimize shrinkage and cracking.
the footing slab will be frost protected. the void below the elevated slabs (floors) is included. convincing the contractor to use epoxy coated rebar will be challenging.
are you making the inside surface out of concrete or are you looking for a shell to hold the tub and a base to set it on...
i have to admit, i'm confused.
the hot tub will be constructed of concrete entirely. it is designed with 3 elements. the upper element flows into the middle element (this will have seating). the middle element folws into the lower element. the floors of all three elements are elevated above the foundation slab. seats in the middle element will also be made of concrete and be poured integrally with the wall (i hope). i hope that the concrete that is exposed to water is somehow protected (cover or coating). any further information from someone who has experience with this type of project is appreciated.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete sampling guidlines huangyhg 产品功能分析 0 2009-09-08 12:34 PM
concrete roof slab load huangyhg 产品功能分析 0 2009-09-08 12:34 PM
concrete mix= reinfocing for exterior composit deck huangyhg 产品功能分析 0 2009-09-08 12:19 PM
concrete corrosion in partial saturated condition huangyhg 产品功能分析 0 2009-09-08 11:54 AM
chapter 4 preliminary design properties of concrete huangyhg 产品功能分析 0 2009-09-07 11:23 PM


所有的时间均为北京时间。 现在的时间是 09:03 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多