dox plank
does anyone know if there are published tables for the allowable load capacity of dox plank? (looks like stack bond masonry spanning horizontally from underside of plank). i looked at an existing roof of an old laundromat yesterday with 16" wide dox plank spanning about 24 feet. the owner wants to cuts some small openings and possibly add some small mechanical units on the roof.
i know little more than that dox was a proprietary system used in inexpensive buildings requiring fire resistance and noise deadening between units, like in a motel.
looking back on revisions made to building code and that so many structures from the 60's (the dox era) are not code compliant by today's standards (especially in areas with snow and drifting), i doubt you'll be able to safely reduce section or increase load.
however, if someone has some information out there on dox, i would like to learn more about it also.
good luck.
what little i know, i will pass along. dox plank where made as you describe, from dox block placed end to end, with rebar threaded through and grouted solid. hence, the 16" wide plank. the reinforcing was 40 ksi mild steel. they were one of the early floor and roof systems that evolved into the prestressed slab industry we see today.
the few times i've seen the system i have called my local prestressed slab supplier for information. they didn't make dox plank, but it was one of there competitors back in the days before prestressed concrete. you might try firms like spancrete, flexicore or fabcon, some of their oldtimers might have some information on it.
i have a 1960 doxplank manual which includes original spec and allowable loading info. let me know if you want something:
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
dox blocks question huangyhg 产品功能分析 0 2009-09-08 07:31 PM
docs plank huangyhg 产品功能分析 0 2009-09-08 07:08 PM
capacity of a beam supporting plank huangyhg 产品功能分析 0 2009-09-07 10:50 PM
adding 1.75 to pc plank for fascia huangyhg 产品功能分析 0 2009-09-07 10:11 AM
2 gypsum plank huangyhg 产品功能分析 0 2009-09-06 10:52 PM


所有的时间均为北京时间。 现在的时间是 02:49 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多