几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量  


返回   几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量 » 三维空间:产品设计或CAX软件使用 » CAD设计 » 产品功能分析
用户名
密码
注册 帮助 会员 日历 银行 搜索 今日新帖 标记论坛为已读


回复
 
主题工具 搜索本主题 显示模式
旧 2009-09-09, 12:10 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 fixed beam-to-column

fixed beam-to-column
hi,
i am just curious what is your opinion: in global analyse of structure beams and columns are represented its axes. generally when i perform a calculation of connection i take internal forces from theoretical intersection of beam and column axes. i am just thinking if it is ok to consider that beam is actually conected on column flange and based on this if it is ok to take the value of bending moment in hc/2 distance from theoretical column axe instead taking the value directly from intersection. what do you think ?
primary i am looking for suggestions consistent with ec3-1-8, but any opinion is welcomed.
lubo
only hope you will understand my poor english...
in the risa analysis program (and perhaps some other programs also) there is a way to identify rigid offsets at joints. these are specified lengths of the ends of the beams and columns that are considered infinitely rigid for analysis purposes.
thus, the bending moments in the beams and columns are taken at the ends of the offsets.
for example. you have a 14 inch column with two 18 inch beams framing into it. the rigid offset length on the beam would be 1/2 the column depth or 14/2 = 7 inches.

yea, i know that ram structural system takes this into account. so, in reality, moment will be introduced into a gravity column based on the eccentricity of the connection. i usually neglect this for low-span construction. this is one of the reasons, my bosses don't like to push columns to unity stress ratio.
one thing to note is that, in general, the moments for an interior column will balance out since you will usually have framing from each side to cancel out. one instance in which i could see it being very significant would be the corner column of a mid-to-high rise building. the moments would add up significantly over the numbers of stories and biaxial bending could be an issue.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
double cantilevered beam equations huangyhg 产品功能分析 0 2009-09-08 07:21 PM
concrete beam to column connection huangyhg 产品功能分析 0 2009-09-08 11:43 AM
concrete beam connection to steel column huangyhg 产品功能分析 0 2009-09-08 11:40 AM
cantilever steel beam at column huangyhg 产品功能分析 0 2009-09-07 10:40 PM
12 x 6.5x 38 thick x 41 residential basement i-beam con huangyhg 产品功能分析 0 2009-09-06 10:30 PM