grp structural desige code and fos
can someone please help me with recommendation for design code for structural grp.
we have a grp post ( cantilevered column, 1.0m height) subject to working load of 80kg (horizontal point load at the top end)
we have carried out a number of destruction tests and they break at 90kg to 120 kg. (different samples fail at different load)
is this sufficient? what should be the factor of safety? what is the governing international code to support the requirement for the fos?
thank you
funnyam
your approach is simplistic and i don't think a design code can cover such design without knowing exact composition of the grp.
as far as i am aware one can analyse a grp section using the exact number of glassfibre filament strands embedded in the defined resin cross section. the structural properties of glassfibre and polyester/epoxy resins are well known and hence the bending resistance of a grp post, assumed to have been manufactured by carefully controlled materials, can be established accurately
i have seen grp pipe designers play around with the number of filament layers and resin thickness, sometimes with ribs, to achieve an economic design. it is a specialised area but the principle is no different from reinforced concrete design except the resin binder in this case has both compressive and tensile strength (concrete's tensile strength is ignored in the reinforcement design). the fibreglass is the equivalent to rebar and the resin is the equivalent concrete.
so it should be possible to prove theoretically the design of your grp post. generally one can add more glassfibre to improve strength untill the amount of resin becomes inadequate to bond all the fibres fully.
in pipe products awwa controlls the grp load carrying capacity by deflection generally around 5% maximum. a safety factor of 1.5 is used for bending.
i am not familiar with any grp code but here goes.
to be consistent with limit state design you should do enough tests (at least 30)to establish that your samples has a normal distribution of failure. once you know statistically that the distribution is normal you can determine the level that 95% of samples would exceed.say f1
fave -(1.645 std dev)f1 should be divided by a partial safety factor to allow for the care in manufacturing, local weaknesses and the criticality of failure.
a live load factor of say 1.5 on your load must give a total less than your calculated f1/fos.
it is therefore evident that this approach would indicate your member needs to be stronger.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
double dipping the safety factor huangyhg 产品功能分析 0 2009-09-08 07:23 PM


所有的时间均为北京时间。 现在的时间是 02:57 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多