默认 lateral bracing

lateral bracing
while it can be done i do not like to use wood as lateral bracing, unless the beam is lightly loaded and the wood joists are spaced no more than 16 inches, o.c.
the compressibility of wood, coupled with the inability to affect a proper tensile connection (from the opposite side) limits its effectiveness in preventing flange buckling.
ron,
i see the point about the condition where joists are only coming in from one side. unless there is a positive connection between the joists and steel beam, the beam could conceivably buckle away from the joists.
but if the joists are on both sides, each providing a positive compressive restraint against sidesway translation, i would think you could consider the beam braced. the small amount of compressibility wouldn't seem to adversely affect the bracing.
if the beam was not heavily loaded, the lateral force, and stiffness required for lateral stability wouldn't be that significant.
what do you think?
we have typically used wood joists as bracing, but admittedly, we usually have the wood on top of the beam.
jae,
i agree with you, just that conditions have to be right for wood to be effective bracing. in most cases it works fine, since as you say, the lateral load to prevent buckling is usually small (less than 500 lbf).
you mentioned the key to getting it to work correctly...make sure both sides in compression at start. often, this is not done and the result is too much movement capability on one side of the beam.
ron
i forget the details but many years ago (maybe 30-35 years) there was a catastrophic steel formwork failure somewhere in the northwest usa or canada. a very complete report of the failure investigation was published. as i recall, one of the main culprits was web buckling of grillage beams which depended on some kind of wood blocking between the beams for web stiffeners. the investigator's analysis proved that the stiffness of the wood blocking was insufficient to prevent the webs from buckling.
i would want to check the joists and joist-steel beam connection details for adequate stiffness, e.g, "bracing for stability", yura & helweg.
it would make sense, bussh, that web buckling wouldn't be resisted properly by wood blocking....the lateral force on a web that buckles would be fairly high. but, web buckling is a local effect, producing high forces locally. lateral torsional buckling is a "macro" effect which, i believe, wood joists, perpendicular to the beam, could probably take care of.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
lateral bracing for long span beam huangyhg 产品功能分析 0 2009-09-10 09:36 AM
lateral bracing for crane bays huangyhg 产品功能分析 0 2009-09-10 09:35 AM
lateral bracing for 100-foot tall free standing steel struc huangyhg 产品功能分析 0 2009-09-10 09:34 AM
inquiry about the theory of tension-only bracing huangyhg 产品功能分析 0 2009-09-09 07:39 PM
bottom chord bracing for cold form trusses huangyhg 产品功能分析 0 2009-09-07 04:28 PM


所有的时间均为北京时间。 现在的时间是 10:24 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多