for a current project i will be designing a concrete shielding enclosure for a linear accelerator in an oncology clinic.
has anyone designed such a sheilding enclosure?
if so, any pointers?
who provided the recommendation for floor/wall/roof thickness and density of concrete requirements? the accelerator supplier? or did the coordinating proffesional (in my case the architect) have to hire an outside consulatant to perform the neccesary calculations, and provide recommendations for the concrete thickness and density.
thank you.
in my experience, the architect hired a nuclear physicist consultant to provide shielding recommendations. based on the physicist's recommendations, we worked with a ready-mix supplier to develop a ultra-heavyweight concrete mix so that the thickness of the walls and slabs was feasible. if i re
have done several of these things in the past. in my experience, it was part of the package provided by the machine manufacturer/supplier (as well as drawings which indicated all of the little "we gotta have" things for the machine like anchorages, blockouts, pits, etc.) the machine manufacturer/supplier hired the physicist who, along with the machine manufacturer, determined the type of shielding (whether concrete, lead, etc.) to be used and its thickness along with the physicist's analysis assumptions and requirements, and provided these to the architect who in turn provided it to me. this was the starting point for discussions or design requirements such as concrete density, different types of shielding, restrictions on air content, etc.
the last concrete one i did, we were given wall thicknesses of 7' within a 10' width from the isocenter of the machine (6' for the ceiling/roof) and 4'0" everywhere else. density for the concrete was only slightly higher than normal concrete - about 165 pcf. someone in the chain determined that, in this instance, it would be cheaper to provide the larger quantities of lighter weight concrete than to provide heavy weight concrete.
coordinating professional hired the consultant.
check with your project owner. find out what kind of contract he has with the supplier. the supplier could provide this information.
i've also done 4-5 of these and my experience goes along with jd2's. the contractors didn't want to consider heavyweight concrete. i think that messed up their trucks.
all:
thank you for your comments and advice. i apppreciate it.
depending on the size and shape of the enclosure, it is possible to get solid concrete block manufactured to very high densities using very dense iron aggregates or even steel shavings.
the block work well for interior applications depending on the logistics and timing relative to the equipment installation. usually, they are made 4" or 6" thick to provide a convenient weight. they are laid in a multi-wythe solid wall using running bond and starting alternate wythes with 1/2 high units.
just as with concrete, it is necessary to recognize the logistics in obtaining the natural or processed aggregates.
dick
prepakt was involved in the design of this stuff in the past
i believe that that this type of biological screening was made by placing iron pyrites, lead or steel pellets in forms (sometimes by hand to avoid voids}and then intruding a concretre mixture into the pellets. way before my time but we may have some specs somewhere if you you dont find any other suitable source of info.
intrusion prepakt /marineconcrete.com
when i've done nuclear shielding, we usually had the option of concrete of `x' thickness or steel of 1/4*x thickness. when you start looking at the amount of floor space you are loosing for concrete, it may make sense in the big picture to go with something denser?
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
how do you know if a problem is linear huangyhg 产品功能分析 0 2009-09-09 05:24 PM
guy tower analysis-linear and non-linear huangyhg 产品功能分析 0 2009-09-09 03:32 PM
linear or ordinate dimensions huangyhg tec-ease(America) 0 2009-09-05 11:33 AM
【转帖】why Not To Display Incorrect To Linear Dimension Indication yang686526 DirectDWG 0 2009-05-07 07:11 PM


所有的时间均为北京时间。 现在的时间是 01:26 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多