默认 local amendment to the code

local amendment to the code
my friend is adding new, steeper 4?:12, roof over existing roof 2:12 of his small one story house. i have designed this new roof framing using 2x6 rafters @ 24" on center in accordance to ibc. after reviewing plans city permit department sent us the following:

a previous building official both enacted and enforced, as others subsequently did (including myself), a local amendment to the code requiring that all wood framing members be a min. of no. 2 grade and no > 16" o.c. -- whereas these drawings note 24" o.c. -- in commercial & residential projects; nonetheless, the local amendment is to the ibc ch. 23 – not the irc – and this project is governed by the irc. with that said, i still have yet to completely & comprehensively review the genesis of the local amendment, such as the minutes of all the meetings involving the building board of adjustment and any applicable city council session(s), in order to come to a determination as to whether the amendment was recorded incorrectly by the previous city secretary and whether or not the amendment was meant to be to the ibc and/or the irc. until i resolve this conundrum, i'll continue to enforce this provision – as it has been enforced since 2004.

putting all rafters on 16" o.c. seems too conservative. since i am not familiar with irc is there any room for "fight"? any advice would be greatly appreciated.

check out our whitepaper library.
there might be. somebody should. maybe you or your friend could appeal the ruling and state your case in front of the appeal board. i'm talking off the top of my head as i am not familiar with either of the codes mentioned.
ba
i would use #2 or better just because less imperfections and knots.
the spacing requirement i think is a stretch and i would just accomodate the request. send the code official the calcs at 24 o.c. and ask he send you an update if he determines the amendment does or does not apply to irc.
mdj
i have no problem with the no. 2 or better, but the 16"o.c. is a bit much.
i agree with mark...show the calcs and rely on the fact that the code is not intended to inhibit innovative thinking, backed by sound engineering judgment.
a possible argument;
more timber = less insulation = increased global warming.
appeal to the president.
while you say that the irc governs, i think that you will find if you your review the governing statues specifying the applicable codes to be used, that if the irc was specified, then the ibc would also have been cited for all buildings.
consequently both codes would be permisable for residential construction. this makes sense because not all residential construction is simple timber frame. there are going to be a few residences (very few) using structural steel or reinforced concrete.

tell him you will sit with him and review the amendment and help him figure out what shoud be what instead of blanket enforcement of a rule he is unsure about.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
icc code article cause for concern huangyhg 产品功能分析 0 2009-09-09 07:00 PM
ada, osha and code violations huangyhg 产品功能分析 0 2009-09-07 10:09 AM
【转帖】no lineweights on bmp-expor yang686526 DirectDWG 0 2009-05-06 06:34 PM
【转帖】nls error yang686526 DirectDWG 0 2009-05-06 06:34 PM
【转帖】newbie question9s0 code compiles, but cannot link yang686526 DirectDWG 0 2009-05-06 06:32 PM


所有的时间均为北京时间。 现在的时间是 04:49 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多