默认 wood studs composite with sheathing

wood studs composite with sheathing?
i have been asked to review an existing wood-framed building. my client wants to look at the wall studs as composite with the exterior osb sheathing. i have never analyzed a wood-framed wall in this way and have a few concerns. one is the shear stress transfer to ensure composite action. another is a thin-flanged beam taking axial load in combination with bending compression.
does anyone know of an established design procedure for this?
i have looked at studs this way. the problem is the sheathing is not continuous, vertically (osb is often laid up horizontally), and so under suction wind load the sheathing cannot help in resisting bending.
about all that can be said is the sheathing reduces deflection.
daveatkins
daveatkins, good point about the discontinuity of the sheathing. if we were able to determine that no joints occur in the sheathing though, do you know of an established procedure? have one of the wood organizations addressed this?
i do not believe the wood organizations have addressed this. it gets back to checking shear flow (vq/i) to verify how composite the section is.
daveatkins
i know one of the metal stud manufacturers (i think clark-western) had some tables for deflection that were based upon non-composite and composite. realistically, however, i would not count on composite action for strength because of the lack of control of the joints, fasteners, spacing, etc.
just based on my experience, if this was a viable application, the engineered lumber companies would be all over it. the last tji i looked at, had an osb web, and solid
thanks to all for the input. i am very skeptical of the composite approach also. just wanted to check whether there is an accepted procedure for this that i didn't know about.
i have looked at and used the concept with the berkley roof panel system to justify smaller members in the past. in that the panels use 8 foot spans between joists, the plywood discontinuity issue never came up in that application.
i had to apply a reduction factor for the plywood based on the ply construction. i wonder how this would apply to osb with the random grain orientation?
mike mccann
mmc engineering
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
wood sheathing to cold form studs huangyhg 产品功能分析 0 2009-09-16 11:11 PM
quality of wood studs today huangyhg 产品功能分析 0 2009-09-15 03:42 PM
line up multi-story wood studs and trusses huangyhg 产品功能分析 0 2009-09-10 10:40 AM
brick cladded wood studs huangyhg 产品功能分析 0 2009-09-07 04:47 PM
adding studs to existing composite beam huangyhg 产品功能分析 0 2009-09-07 10:13 AM


所有的时间均为北京时间。 现在的时间是 12:37 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多