concrete cover
hi,
i have a situation where a concrete beam has been poured without the specified cover for reinforcing steel stirrups on one side. i have checked shear and torsion and one leg of the ties would be sufficient. can one consider rendering the beam with a 3:1 sand:concrete mortar to provide the necessary cover?
thanks
it could be ok... small diametre main bars? is bond an issue? and any problem with fire resistance?
dik
render is quite porous, so i dont think it will have any benefit at all.
you should use a concrete repair mortar and bonding agent made specifically for patching spalled concrete. google it.
could you simply paint it with intumescent paint?
jae
i am more concerned about corrosion since the structure is close to the sea. any comment about the render?
thnx
a few examples of products to do it the correct way.
there are placement tolerances for cover and stuff like that. chapter 4 or 5, i think. depends on how much you have in the first place.
if you are going to bother fixing it then use a proper product such as the ones mentioned. you generally need a bonding agent too so it sticks properly.
what is the cover?
hi
we have about 15mm right now
i agree with csd's recommendation for a repair-type mortar with a corrosion inhibitor included in the material.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete cover w vapor barrier huangyhg 产品功能分析 0 2009-09-08 11:57 AM
concrete cover for water tight concrete huangyhg 产品功能分析 0 2009-09-08 11:57 AM
concrete cover at reinforcing couplers huangyhg 产品功能分析 0 2009-09-08 11:56 AM
concrete corrosion in partial saturated condition huangyhg 产品功能分析 0 2009-09-08 11:54 AM
chapter 4 preliminary design properties of concrete huangyhg 产品功能分析 0 2009-09-07 11:23 PM


所有的时间均为北京时间。 现在的时间是 05:43 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多