hot rc structure (sulfur pit)
we are evaluating a design for a sulfur pit. it is essentially a rc box below grade, with removable rc lid panels. the interior is lined with 1/4" thick 316 stainless steel. the sulfur storage temperature is 300 °f.
does anyone know of a good reference that deals with evaluating the thermal stresses in such a structure? my main concerns are:
1.) large moments at the corners due to each panel (floor, wall, etc.) trying to assume a curved form due to differential expansion and being restrained by adjacent panels. assume a linear temperature profile across the wall thickness.
2.) determining the proper spacing of the shear studs that connect the stainless liner to the concrete. it is desired to have composite action between the liner and concrete. the stainless steel expansion is very large. how is this accomodated?

if you want composite action you can't get it but for complete transfer of the worse shears that develop, that will be those occurring when the concrete is cold and molten sulphur is poured.
each stud will need to restrain forces of inter-studs compression developing at the differential elongation.
that is, take an entire square module, and find what force would cause the same elongation than the differential elongation the sulphur causes between the concrete and steel when it is poured.
this force should be a conservative statement of the capacity required of each stud.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
hand calculations for a slender beam-column structure huangyhg 产品功能分析 0 2009-09-09 03:47 PM
equipment vibration huangyhg 产品功能分析 0 2009-09-08 10:44 PM
cable roof structure huangyhg 产品功能分析 0 2009-09-07 06:03 PM
ordinate dimensions to define gdt datum structure huangyhg tec-ease(America) 0 2009-09-05 11:59 AM
【转帖】ordinate dimensions to define gdt datum structure yang686526 American standards 0 2009-04-29 09:04 PM


所有的时间均为北京时间。 现在的时间是 06:05 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多