performance vs prescriptive concrete
does anyone have any views or worked with performance based concrete, and what type of testing during placement was called out for, and what the results were? i am looking at special inspection testing of plastic concrete, and the results, including any comparisons to a similar (ingredient type and amounts) prescriptive mix.
this is an interesting subject i'd like to learn more about.
i first heard of the term "performance concrete" from ready mixed concrete salesmen back in the 80s. back then most of it was used on residential projects where strengths were generally between 2,000 psi to 3,000 psi. the mixes were usually classified on the basis of msa and strength...which meant slumps in excess of 6 inches was not uncommon.
fast forward to the present. most concrete mixture proportions in the us are still based on a prescriptive design methodology. nontheless there are organizations that are strong proponents of performance concrete.
nrmca have been a powerful advocate for the use of performance concrete. however, to make widespread use of performance concrete for major structural concrete work a reality in the united states, it would be prudent for nrmca to work with powerful organizations like aci to develop an astm standard that will be referenced by codes like the ibc.
the april 2005 edition of structure magazine had an interesting article on it which was consistent with the nrmca p2p initiative
henri2,
i have recently attended an aci meeting regarding the documents from nrmca, with alot of discussion on who is responsible, how it will work, what challenges remain. but city of seattle building code requires a certain amount of cement for a certain strength level. if the suppliers want to use less cement, we then look at the mix performance over a period of time, and if it works, we grant it 'continuous approval' where only the engineer needs to approve the mix. so if we were to look at 'performance' mixes, we would be eliminating a system that has provided some of the best concrete construction this side of the mississippi. nedless to say, there are some concerns. we are also concerned over the field testing that, from what they say, will be no longer needed. another is the new tests, the cost, and the time to perform them. yea, its a whole new ball game.
i think it is something that we will be leading into, and accepting, but i would rather avoid any problems by seeing what other jurisdictions or suppliers or design profesionals have done, and modeling ouprogram after that.
i was not aware there was a concrete forum, so i will be moving any further questions over there.
thanks for the reply and the web links!
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
concrete sampling guidlines huangyhg 产品功能分析 0 2009-09-08 12:34 PM
concrete mix= reinfocing for exterior composit deck huangyhg 产品功能分析 0 2009-09-08 12:19 PM
concrete corrosion in partial saturated condition huangyhg 产品功能分析 0 2009-09-08 11:54 AM
chapter 4 preliminary design properties of concrete huangyhg 产品功能分析 0 2009-09-07 11:23 PM
【转帖】asme美国机械工程师标准目录2 huangyhg American standards 5 2009-04-26 02:38 PM


所有的时间均为北京时间。 现在的时间是 03:47 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多