默认 site inspection for apparent snoe drift issues

site inspection for apparent snoe drift issues
i have been asked to make an urgent trip to inspect a building about which the owner is concerned because some ceiling tiles have dropped out apparently due to snow and ice build-up. the builder has already made an inspection and apparently the bottom flange of a pemb roof beam is kicking out slightly (1.25" over 60').
as i make preparations for the trip i was wondering about some of the precautions others are taking when perfomring this type of service. they want me to inspect and address this issue in particular and write a letter either stating that it is not an issue or if so what corrections need to be made. my concern is that by being there and seeing the building could i be responsible for other issues which i may not see? is it possible to to limit my responsibility to this issue in particular or am i bringing much more on myself than i realize. obviously if i would see other issues i would bring it to the owner's attention but i would not be going with the intent of reviewing other aspects of the building.
i welcome any thoughts on this,
thanks,
check out our whitepaper library.
you need to see the plans and specs of the pre-engineered building in order to see if the design matches the as-built situation. the snow load and drifts are partially dependent on heated vs. not heated and installation of ice breakers. the horizontal deflection may be normal and expected for the steel frame but not used in the design of interior components, (t-bar suspended ceiling tiles with exterior edges attached to walls).
civilperson,
thanks for the quick response. yes i have made the owner aware that i can only speak to the erection tolerances and any obvious distress that i see in the structure. as far was whether the structure can handle the load that is being applied to it is going to depend on what an in depth review would show. from talking to some people who know the history of this building it sounds like it has received much more load in the past during the snow storms of the early to mid 90's without incident. i belive that the out of plumbness of the roof beam has always been and that this is not something that has developed recently since none of the flange braces have buckled or thier holes elongated. now i am just trying to determine what the allowable out of plumbness is for a roof beam, but i guess that is another thread.
the reason i was worried about being liable for other issues was because i had heard a story from an engineer that i know who got called into a deposition simply becasue he was in a building that later collapsed under snow load. even though the reason for his visit had nothing to do with inspecting the building to be sure that it had been properly constructed. so i was just wondering what sort of premptive steps i could take to help prevent this from happening to me.
thanks,
if you are associated in any way with a building involved in a lawsuit, you can be asked for a deposition. this will only include facts and factual observations. if they want your expert testimony and opinion, the attorneys must pay for the opinion. this is one drawback of our judicial system, facts must be produced for free: only opinions get paid for.
i would state in the written report what i was looking at. i also would include some language like: my scope of work was .... my site visit can not be construed as a complete inspection of the structure as a whole....
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
metal bldg drift w brick veneer huangyhg 产品功能分析 0 2009-09-10 01:34 PM
inspection symbols with gd huangyhg tec-ease(America) 0 2009-09-05 11:23 AM
【转帖】inspection symbols with gd yang686526 American standards 0 2009-04-29 08:32 PM
【转帖】asme美国机械工程师标准目录2 huangyhg American standards 5 2009-04-26 02:38 PM
PC-DMIS Inspection Planner huangyhg PC-DMIS 0 2006-12-04 11:09 PM


所有的时间均为北京时间。 现在的时间是 08:27 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多