默认 grade beam construction joints

grade beam construction joints
anyone know of a code mandated construction joint distance? i have a typical wall construction joint distnace not to exceed, and now the question has come up - "what about the grade beams, then?".

i've never used any mandated spacing of construction joints in concrete grade beams. the spacing of cj's are left up to the contractor which depends upon crew size, availability of concrete, etc.
in the past, i have specified a limit of 400 cy of concrete in one day's placement - but haven't done that for a while as i think it invades the means and methods of the contractor.
in terms of controlling cracks, etc., i wouldn't think it necessary to use cj's at all unless the grade beam is some kind of wall system where large areas of concrete were exposed to view. in that case, i'd probably specify vertical formed goove joints near midspan.
i know of no code mandated requirements for spacing of joints. in aci 350, there used to be a chart or table that gave recommended percentages of steel for different joint spacing. keep in mind that this is for sanitary engineering structures, not buildings but it can give you some guidelines. i do not know if the chart or table is in the latest version of that code.
the larger amount of longitundinal steel, the farther apart the spacing of the joints can be. the steel helps reduce the cracking. since a grade beam typically has more longitundinal steel than a wall, the spacing between joints can be further apart than walls.
during the wpa programs of the 30's, many gravity retaining walls (railroad grade separation projects) were poured with no longitudinal steel. if i recall correctly, they limited the joint spacing to 20 feet. this, therefore, could be considered as a lower bound for joint spacing with no longitudinal steel.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
construction joints in conc pedestrian tunnel huangyhg 产品功能分析 0 2009-09-08 01:27 PM
concrete tanks - vertical construction joints in walls huangyhg 产品功能分析 0 2009-09-08 12:55 PM
concrete grade beam huangyhg 产品功能分析 0 2009-09-08 12:13 PM
beam strengthening huangyhg 产品功能分析 0 2009-09-07 03:04 PM
12 x 6.5x 38 thick x 41 residential basement i-beam con huangyhg 产品功能分析 0 2009-09-06 10:30 PM


所有的时间均为北京时间。 现在的时间是 02:38 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多