旧 2009-09-16, 05:07 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 underground sanitary tank - lid attachment joint spacing

underground sanitary tank - lid attachment & joint spacing
i am designing an underground sanitary tank. what would be the best way to connect the lid (either cast on the ground and craned on top or pre-stressed craned on top) to the walls to give walls stability to resist deflection from backfill loads?
i was thinking of dowelling and epoxy into the top of the walls thru holes in the lid and epoxy to seal - what do you think?
regarding contraction joints; 60 feet is maximum length of wall recommended without joints with 30 to 50 feet being more common, would you consider that length measured along each wall or measured along the tank length?
for example: sanitary tank 60 feet long x 15 feet wide with 4 compartments of various sizes.
do you add the perimeter dimensions to determine the need for joints in this case 150' or just go by the tank length of 60' and that would not require any joints?
no joints needed. if used, put waterstop at center of wall thickness.
am i pushing the envelope if i do not use any joints?
which presents the most risk; installing a joint that may leak or not installing any joints and the cracks that develop may leak??
joints will almost always leak no matter how careful you are. cracking will occur, but as long as it is controlled to small crack widths by adequate crack control reinforcement, it may not leak. even if it does leak, autogeneous healing will help.
if you don't ever need to remove the lid, cast prestressing ducts into the top of the wall and into the edge of the lid. insert dowels and grout.
if you need a removable lid, cast the lid thicker inside the wall to create a bearing lug.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
ank bottom in submerged tank - rising water level huangyhg 产品功能分析 0 2009-09-16 12:43 PM
difference between a construction joint and an expansion joi huangyhg 产品功能分析 0 2009-09-08 06:40 PM
control joint spacing huangyhg 产品功能分析 0 2009-09-08 01:44 PM
buoyancy of underground tank huangyhg 产品功能分析 0 2009-09-07 05:53 PM
8000gal water tank foundation design huangyhg 产品功能分析 0 2009-09-07 08:59 AM


所有的时间均为北京时间。 现在的时间是 08:08 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多