默认 wind loads for decorative awnings

wind loads for decorative awnings??
i'm trying to get my arms around a reasonable wind load to use for an architectural feature (an awning ≈ 140 sf) on a building i'm working on. it will be a fabric, to be determined later, it will have an irregular shape oriented in an irregular manner supported by a steel/aluminum framework spaced about 20' apart.
my first thought was to use component/cladding loads, but after pushing numbers i can't imagine an awning like this anywhere designed for these load magnitudes.
anybody have any thoughts or experience with this type of beast?
the couple projects i've seen involving similar structures have found it more econmical to design the frame based on the fabric breaking strength and replace the fabric after significant events.
where do you get the info about fabric breaking strength?
tyically, fabric awnings should be closed during a design wind event. in any case, it's not a life safety issue if it fails, unless the flying debris hits somebody... but then again, there's all other kinds of debris flying around anyway. i doubt seriously if awning manufacturers design their fabric awnings for 100-year wind loads.
i am working on a project where the owner wants to add fabric awnings to an existing multi-story building in a downtown area. there are no structural drawings for the building and the owner will not allow any demo to expose the existing structure for field measurements. the owner wants to attach the awnings to precast concrete veneer panels. the owner wants me to say the awnings and connections to the veneer panels meets code so he can get a city permit. so far, i have found no reasonable way to help him.
search
are you designing it for catenary loads from the fabric? the reaction perpendicular to the wind can often be only one fifth(or less) of the total tension in the fabric.
sunsetter is a supplier of power operated awnings. this version is cantilevered off the wall. it would be worth looking into their catalog and discussing your concerns with their people. i have seen them, and they give a good impression. naturally, it should be retracted in a strong wind.
are you designing it for catenary loads from the fabric? the reaction perpendicular to the wind can often be only one fifth(or less) of the total tension in the fabric.
this is one of the main reasons behind designing for the fabric breaking strength, not the actual loading. it is also generally easier to get a hold of breaking strengths than elasticity values from my experience. as far as i've seen elasticity is not a common testing criterium.
other posters have pointed to some sites/companies for material information, but a canvas of local suppliers would also get you the relevant information.
as for structural impact on the building, it's worth taking a look at what the loads actually are. chances are the wind loading on the awning adds almost no net load to the building, as it shields surfaces behind it, and the overall weight of the structure may be insignificant. generally the main concern when adding this sort of structure is the anchorage. if you cannot determine what you are anchoring to then you are in trouble.

gwyn,
i understand what you are getting at, but what if your fabric breaking strength is much graeter than it needs to be? even if it is not then you have no guarantee that your individual piece is not 20% stronger!
we get this issue with mesh banners and signs so in this case we have to design it for the full catenary action. the elasticity is hard to come by but we have usually found that the test data sheets show elongation at various stages during the testing which can be used to estimate ea.
i have designed similar structures based on the breaking strength of the clasp/careens. a recent project had stainless steel m12 bolts with a specified breaking strength of 1.2t. this is below the calculated force based on catenary loading and is certainly easier to justify and resolve. (i put a 1.5 s.f to get over the hump in the bell curve).
perhaps you could specify a frangible fixing yourself - just be sure you aren't around when the magic load is reached - your could lose an eye... or a limb
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
回复


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
what wind loads on building canopy huangyhg 产品功能分析 0 2009-09-16 08:36 PM
ransient loads huangyhg 产品功能分析 0 2009-09-16 03:35 PM
emporary wind loads huangyhg 产品功能分析 0 2009-09-16 01:09 PM
asce figure 6-10 wind loads huangyhg 产品功能分析 0 2009-09-07 01:22 PM
are asce 7-02 wind loads ultimate or service level huangyhg 产品功能分析 0 2009-09-07 12:46 PM


所有的时间均为北京时间。 现在的时间是 09:25 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多