几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量  


返回   几何尺寸与公差论坛------致力于产品几何量公差标准GD&T (GDT:ASME)|New GPS(ISO)研究/CAD设计/CAM加工/CMM测量 » 三维空间:产品设计或CAX软件使用 » CAD设计 » 产品功能分析
用户名
密码
注册 帮助 会员 日历 银行 搜索 今日新帖 标记论坛为已读


 
 
主题工具 搜索本主题 显示模式
旧 2009-09-07, 02:09 PM   #1
huangyhg
超级版主
 
huangyhg的头像
 
注册日期: 04-03
帖子: 18592
精华: 36
现金: 249466 标准币
资产: 1080358888 标准币
huangyhg 向着好的方向发展
默认 baffle plate thickness for a rectangle tank

baffle plate thickness for a rectangle tank
please help kindly help. there is metallic rectangular tank, where liquid is stored. (on any one half). there is a plate (baffle plate) which divides the tank into two. the baffle plate and the tank assembly is in a civil pit. baffle plate is welded on both sides on insert plates of the civil pit and baffle plate is not supported at the bottom.
hence the weight of the tank of 6 tons and additional load of liquid in any one half which is 7.8 ( total 13.8 tons) is acting on baffle plate. that means baffle plate is acting as a beam fixed at both sides,

and a load is acting from 1350 mm from one edge to 3300 mm and again there is a gap of 1350 mm till the another fixed end.
| 1350 | 3300 | 1350 |
--------------------------------
x m n y
consider liquid is present only in one section say section a marked on the sketch which

1.1x 3.3x 1.8 = 6.534 cum

weight is 6.534 x 1.2 (density) = 7.8 tons (max)

box weight is 3.5 tons. (approximately as given by vendor)

now the baffle plate is fixed at point x and point y , point m and n are the places where weight of the box and the liquid act on baffle plate. baffle plate is welded at x and y but not rested on floor

therefore baffle plate 6 meter length ( x and y) ( 1.8 meter height and about 6 mm thk) is considered a fixed or simply supported beam

do u think the thickness 6 mm sufficient?
how to actually see buckling case?
how to check for compression case?

can you kindly help me with calculations please.

could not find sketch. could not find section a. which dimension is depth? how is tank weight loading the baffle plate? assume tank length is 6 meters; assume tank width is 2.2 meters which is divided by baffle plate, giving 1.1 meters on both sides; and assume depth is 1.2 meters. the center space volume is holding 7800 kilograms of liquid which has a triangular pressure distribution of zero at the top and 1440 at the bottom. the model of the baffle plate that i arrive at, is a continuous beam with three spans, fixed at the outside ends and supported on hinges at points m and n. i can see no case of buckling, just flexure or bending stress on the 6 mm thick plate/beam. more details or confirm my assumptions please.
is this also the tank that contains molten sulphur?
mike halloran
pembroke pines, fl, usa
confusing, isn't it? i think what he is saying is that the "baffle plate" is spanning 6 metres and carrying this tank which is loaded on one side of the baffle only. my interpretation of the tank is that it is 3300 long, 2200 wide, and 1800 deep, divided into two compartments each 1100 wide. whole thing is supported only on the centre 1800 deep x 6000span plate. so what takes the torsion when one side only is loaded?
by "tons", i take it tonnes is meant.
the "box weight" is 3.5 tonnes, but the "tank weight" is 6 tonnes. is that because you have factored the vendor's load?
sounds like you will need a horizontally spanning
hello civil person/mike/ hokie,
i am sorry i could not able to upload the sketch. civil person, tank is 2200 width, 3300 length, 1800 height
baffle which devides the tank into two half of 1100 each
baffle plate lenth is 6000 and 1800 height
so baffle extends over tank wall by 1350 both sides
( 6000- 3300 = 2700 and 2700/2 = 1350
but baffle plate is fixed at the ends x and y but not supported .
all dimensions in mm and box and tank are same . yes it is for sulphur. liquid weight + tank weight is 7.8 tonnes
don't get what you mean by "baffle plate is fixed at the ends x and y but not supported." i thought x and y were your supports. if that is the case, my previous post seems to have all the right assumptions, and you need a top and bottom horizontally oriented member to prevent rotation of the tank when loaded in only one cell.
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
analysis of submerged flat plate huangyhg 产品功能分析 0 2009-09-07 11:39 AM
a column at center of tank bottom plate huangyhg 产品功能分析 0 2009-09-07 09:03 AM
8000gal water tank foundation design huangyhg 产品功能分析 0 2009-09-07 08:59 AM
10 ft continuous weld beam to cover plate huangyhg 产品功能分析 0 2009-09-06 10:26 PM
【转帖】asme美国机械工程师标准目录2 huangyhg American standards 5 2009-04-26 02:38 PM


所有的时间均为北京时间。 现在的时间是 12:46 AM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多