cantilevered steel i-beam capacity
should be a simple question for a structural engineer. i need to lift a fountain from a lake and plan to rig a cantilevered steel 6"w x 4"h i-beam of .25" thickness. a 12" wooden piling will support the middle of the 11 foot beam and the rear will be well anchored to two pilings. what weight could i expect the cantilevered five-foot section to support? the fountain weighs about 1000 lbs and with chain fall and lifting sling, the total supported weight would be about 1100 lbs. would a 6"w x 6"h i-beam be a better choice? any help would be appreciated. thanks
as per my advice to all looking for a definitive answer, see a local engineer, do not seek an exact solution here.
sc
hi rodkent
depending on how the pilings are attached to the beam it may not be a cantilevered beam it maybe a simply supported beam in which the supports are not symmetricaly placed about the beam centre. if your case is a cantilevered beam then you have a beam which is statically indeterminate, to expand a little a cantilever beam is a beam that is built in at one end and supported such that the built in end is not free to rotate in the plane of the load.please confirm
how the wooden pilings are attached and i maybe able to help you further.
regards desertfox
desertfox,
thanks for your reply. maybe what i plan is not actually a cantilevered beam, but is depicted below. total length of the main i-beam is 11 feet with the center resting (unsecured) on a 12" diameter wooden piling. the rear is bolted to the bottom of a purpendicular 48" i-beam that is secured to two 12" diameter wooden pilings with large lag bolts through welded end flanges. the rear support pilings are spaced 48" apart.
the desired result is to hoist an 1100 pound load with the unsupported end of the beam using a chain fall. the middle support piling is at the end of a deck and this arrangement would give me a five foot reach out over the water to hoist the fountain. would the 6"w x 4"h, .25" mild steel beam be expected to bear this load without buckling or should i use a 6x6 beam, or support the outboard end of the beam with a brace?
plan view of pilings:
o
o
o

elevation view of beam:

============================x 48" i-beam (end view)
o chain fall || main beam bolted under
| || cross beam at rear
^ sling ||
/ \ || beam resting on 12" dia.
load piling at middle

any help will be appreciated, but the worst case is that the fountain falls back into the lake. no liability problem here
thanks,
rod kent
hi rodkent
nearest info i could find here was a 6"x6" x 16lb/ft web thickness 0.24".
now i am only considering the beam and not the strength of the pilings.
using simply supported beam theory i estimate using a 5'.6"
overhang the following figures:-
reaction at centre support piling= 2200lb(acting
skyward)
reaction at the main beam end = 1100lb (acting down to
floor)
max bending moment on i beam is at centre support = 6050lbft
max bending stress in i beam = 7177,65 lb/in^2
for a beam of this size made from 43a grade material (steel)
the above stress would only be about 1/10 of its minimum tensile strength therefore:- the beam itself would do the job, however this assumes that the beam is loaded in bending only and that the supports can safely react the forces given above, this is about the best i can do,
regards desertfox
desertfox.
thank you for this analysis. prompt, thorough, and useful.
rod kent
__________________
借用达朗贝尔的名言:前进吧,你会得到信心!
[url="http://www.dimcax.com"]几何尺寸与公差标准[/url]
huangyhg离线中   回复时引用此帖
GDT自动化论坛(仅游客可见)
 


主题工具 搜索本主题
搜索本主题:

高级搜索
显示模式

发帖规则
不可以发表新主题
不可以回复主题
不可以上传附件
不可以编辑您的帖子

vB 代码开启
[IMG]代码开启
HTML代码关闭

相似的主题
主题 主题发起者 论坛 回复 最后发表
cantilever steel beam at column huangyhg 产品功能分析 0 2009-09-07 10:40 PM
built-up section - steel spreader beam huangyhg 产品功能分析 0 2009-09-07 05:49 PM
bottom flange bearing on steel beam huangyhg 产品功能分析 0 2009-09-07 04:29 PM
beam strengthening huangyhg 产品功能分析 0 2009-09-07 03:04 PM
12 x 6.5x 38 thick x 41 residential basement i-beam con huangyhg 产品功能分析 0 2009-09-06 10:30 PM


所有的时间均为北京时间。 现在的时间是 12:16 PM.


于2004年创办,几何尺寸与公差论坛"致力于产品几何量公差标准GD&T | GPS研究/CAD设计/CAM加工/CMM测量"。免责声明:论坛严禁发布色情反动言论及有关违反国家法律法规内容!情节严重者提供其IP,并配合相关部门进行严厉查处,若內容有涉及侵权,请立即联系我们QQ:44671734。注:此论坛须管理员验证方可发帖。
沪ICP备06057009号-2
更多